Float type level meters
FXL series
- Float type liquid meter for compactness and multiple functions
-
Can measure a wide range of materials (It can measure the level even when the physical characteristics of the liquid change). Can measure levels stably even in harsh conditions.
Respond to changes in the electrical characteristic of the material to be measured. A variety of coupling types are provided, including standard flange, ferrule connection, and screw-in connection types.
Features, keys |Usage, use examples |Standard specifications
Features, keys
- Can measure a wide range of materials
Not affected by electrical characteristic changes of the materials to be measured. It is not affected by temperature, pressure, or gas in the tank. - Safe design that endures harsh tank conditions
Can be used in various conditions including water-proof housings (protection class IP68), detection section can withstand a pressure of 1 MPa and heat resistant to 100 degrees. - Simple measurement settings
Simple initial settings (press buttons) for measurement. A small non-sensing area makes measurements possible over a wide range. - Many functions for safety measurement as standard
A delay setting function and watch dog function come as standard.
Usages, use examples
- Works across a wide range of liquids, (and can even measure after the liquid type is changed, or the electrical properties of the liquid change)
Standard specifications
Amplifier
Power source required | 20 to 250 V AC/DC |
---|---|
Power consumption | 1.5 VA or less |
Ambient operating temperature | -10 to +60 degrees |
Current output | 4 to 20mA DC (maximum load resistance: 500Ω or less) 4.0mA output at 0% of registered value 20.0mA output at 100% of registered value |
Response speed | Approx. 0.5sec to 180sec adjustable |
Data output (optional) | Conform to RS485 |
Sensor
Model name | Standard flange type | Standard ferrule type | Standard screw-in type | |
---|---|---|---|---|
FXL-13N1-R1110JH1 | FXL-13N1-R1110DR1 | FXL-13N1-R1110RH1 | ||
Connection | Dimensional standard *1 |
JIS5K50A FF (can be altered on request) |
IDF/ISO 2.5S (can be altered on request) |
R2 (can be altered on request) |
Materials | SUS304 (SUS316 as option) | |||
Float | Outside diameter | Φ50xH48 | ||
Materials | SUS316L | |||
Measurable specific gravity |
0.55 or more | |||
Stem | Outside diameter | Φ13mm | ||
Materials | SUS304 (SUS316 as option) | |||
Length | Maximum 3000mm *2 | |||
Others | Detection interval | Maximum 8mm | ||
Non-sensing zone | When specific gravity is 0.55, 57mm at stem tip and 1mm at the case When specific gravity is 1.00, 36mm at stem tip and 22mm at the case |
|||
Operating temperature: | -10 to +80 degrees | |||
Operating pressure | 1MPa *3 | |||
Protection level | IP68 | |||
Painted color | Dark blue equivalent to Munsell 5PB3/8 |