Float type level meters
FXL/FXD level gauge type
- Measure the liquid level inside the level gauge without contact from the outside of the tank
-
A special float is inserted into the liquid level inside the gauge to measure from the outside. Unlike the conventional contact type, continuous signal output is possible. The main body is made of SUS304 and has excellent corrosion resistance, and the length can be freely designed.
Two types are available: non-explosion-proof type (FXL) and explosion-proof type (FXD).
Features, keys |Usage, use examples |Standard specifications
Features, keys
- Safety design that does not damage the gauge or leak
- Structure that is easy to see and stain-resistant due to the color coding of the display surface
- Long visible range and lightweight
- Excellent pressure resistance, heat resistance, corrosion resistance, earthquake resistance, weather resistance
- A pressure-resistant explosion-proof type that is ideal for dangerous goods tanks under the Fire Service Act is available
Usages, use examples
- Continuously measures liquids in a small tank or small container. Ideal for replacing a conventional liquid level switch.
- Works across a wide range of liquids, (and can even measure after the liquid type is changed, or the electrical properties of the liquid change)
- Hash environments of extreme temperatures, and positions not easy to maintain or check.
Standard specifications
Amplifier
Model name | FXL level gauge type (non-explosion proof) | FXD level gauge type (explosion proof) |
---|---|---|
Power source required | 20 to 250V AC/DC | |
Power consumption | 1.5VA or less | |
Ambient operating temperature | 0 to +60 degrees | |
Current output | 4 to 20mA DC (maximum load 500Ħ or less) | |
Wiring port | G1/2 | Dedicated cable ground |
Option | RS-485 |
Sensor
Model name | FXL level gauge type (non-explosion proof) | FXD level gauge type (explosion proof) | |
---|---|---|---|
Connection | Dimensional standard *1 | 50A (Φ60.5) | |
Materials | PP | ||
Specific gravity of measurable liquids | 0.6 or more | ||
Measurement range | 0 to 5500mm | 0 to 4000mm | |
Operating temperature | -50 to +320 degrees | ||
Operating pressure | -0.1 to 5MPa | ||
Protection level | IP55(drip-proof) | IP65 | |
Explosion-proof | - | Exd‡UBT4 |