HOME > Level meter (continuous type) > Submersible hydrostatic level meter series

Submersible hydrostatic level meter

HLM-25S series
HLM-25S series
Submersible hydrostatic level meter capable of continuous level measurement of normal water from 1 to 100 m
 

Ideal for continuous level measurement of normal water in a long range of 1 to 100 m. Measures the continuous level of normal water (clean liquid such as tap water). Equipped with temperature compensation function and surge protection circuit..

Two types, current output type and voltage output type, are available.
Intrinsically safe models are also available.

  • For liquid

There are two models, one for normal water (clean water such as tap water) and the other for sludge, drainage (slightly dirty water). HLM-25S is usually for water.

 

Features, keys

  1. Can measurement continuous level measurement of water from 1 to 100 m
    Normal water (clean liquid such as tap water) HLM-25S type
    * Applications: Water such as non-pressure tanks, drill holes, wells, pool water, etc.
    Different liquids need to be set at the time of purchase.
    * Sludge water, drainage, etc. (slightly dirty water) HLM-25C type
  2. No settings or adjustments required
    No other settings or adjustments are required just by wiring. Easy to handle such as installation and maintenance.
  3. With temperature correction function
    Equipped with an accuracy correction function due to changes in water temperature.
  4. With surge protection circuit
    Protects against abnormally high voltage and abnormally large current caused by voltage polarity reversal and lightning.
  5. Intrinsically safe type
    Intrinsically safe type is also available for tanks with an explosive atmosphere.
  6. When the liquid density is constant, the pressure at the tip of the sensor is proportional to the water level. A signal is output from the relative pressure between this pressure and atmospheric pressure.
 

Usages, use examples

  • Normal water (clean liquid such as tap water) such as non-pressure tanks, drill holes, wells, pool water, etc.
 

Standard specifications

Model name HLM-25S-I
(Current output type)
HLM-25S-U
(Voltage output type)
Measurement range 1 to 100m (specified at the time of ordering)
Power source required 12 to 36V 16 to 30V
Current output 4 to 20mA DC (maximum load 500 *1)
Power consumption (When no load) 4mA less than Maximun 8mA
Allowable pressure load 1.5 x measurement range
Accuracy *2 0.5% F.S. (maximum 0.7 F.S.)
Long-term stability 0.3% per year
Temperature error *2
(0 to + 50 degree)
Max.0.04% per degree (Measurement range 1-5m)
Max.0.03% per degree (Measurement range 5-10m)
Max.0.02% per degree (Measurement range 10-100m)
Operating temperature 0 to + 50 degree
Operating ambient temperature -20 to + 70 degree
Protection class IP68
Materials Probe: SUS303, Membrane: SUS316L
Sensor protection cap: HDPE, Cable coating: PE,
Cable gland: Silicon
Weight Sensor: 190g, Cable: 60g per m

*1: The maximum load resistance of 500 in the current output specifications is the value when the power supply voltage is 24V.

*2: This accuracy and temperature error may vary depending on the object to be measured and the usage environment.