Vibration type level switches
CV-SED series
- Reliably detects sediment or deposits in liquid
-
Reliably detects solids (sediment, deposits) in liquids.
Sensitivity can be set for the liquid’s specific gravity and the type of sediment using the sensitivity selection switch.A variety of sensor types are available such as our standard, an extension probe type, a hanging type, etc.
Features, keys | Line up | Usages, example of use | Standard specifications
Features, keys
- Ideal for all solid-liquid separation devices
This sensor is designed to detect sediments in liquid, such as sand and mud, sludge, and also pellets. If the sensor in the liquid comes into contact with sediment, or is buried in it, the sensor switch will output a relay signal. - Sensitivity can be set to match the conditions of use
The sensitivity can be set to match the liquid’s specific gravity and the type of sediment. By adjusting the sensitivity select switch, you can tune the sensor switch for even better optimum to the condition. - A variety of functions are included
A wide range of power supplies (20 to 250VAC/DC), fail-safe function, and CE marking.
Line-up
Model name | CV-210-RD-SED | CV-310-RD-SED | CV-510-RD-SED |
---|---|---|---|
Type | Standard type | Extension probe type | Hanging type |
Features | Sensor switch dedicated to detecting the amount of sediment in a liquid | You can specify the probe length for your conditions. |
Can be used in deep-sea detection, up to 20m below the surface. You can specify the probe length for your conditions |
Major applications | Detects the quantity of sludge in washing liquid, or mud and sand in water. Mainly used for mounting the housing horizontally |
Mainly used for angled and vertical installations in upper positions |
Ideal for use in underground pits and deep wells. |
Photograph |
Usages, use examples
Detects heaps of sludge in washing liquid, and mud and sand in water.
Standard specifications
Model name | CV-210-RD-SED | CV-310-RD-SED | CV-510-RD-SED | |
---|---|---|---|---|
Amplifier | Input power source | 22 to 250 VAC/DC | ||
Configuration of output contact points | 2c (DPDT) | |||
Output contact point capacity | 200V AC 80W DC | |||
Maximum open/close voltage | 250VAC | |||
Maximum open/close current | 8A | |||
Power consumption | 3VA | |||
Allowable amplifier temperature | -40 to +70 degrees | |||
Housing | Protection class | IP67 | ||
Material | Die-cast aluminum | |||
Wire outlet hole | M20~1.5 (2 pieces) | |||
Detection probe |
Connections | R1-1/2 (many optional flanges are available *1) |
R1 1/2 (many optional flanges are available) |
R1 1/2 (many optional flanges are available *1) |
Material | SUS304 | SUS304 | SUS304, polyurethane | |
Allowable temperature | -40 to +80 degrees | -40 to +80 degrees | -40 to +70 degrees | |
Maximum allowable pressure *2 | 1MPa | |||
Allowable load | 100N (offset load) | ― | 200Kg (tensile load) |