Vibration type level switches
SHT series
- A level switch for high temperature that has attained the best heavy load performance and high sensitivity in its class
-
Ideal for detecting levels of powder and granulated materials at high temperatures. Can detect almost all powders, granules, and lumps.
Attained the best high sensitivity (nominal specific gravity of 0.02) an best end load (1 kN) in its class, and can be used in harsh environments.
Features, keys |Line up |Usages, use examples |Standard specifications
Features, keys
- Best high sensitivity level (detection is possible at a nominal specific gravity of 0.02) in the class
It can detect various powders, incinerated ash, and fine powders. - Can operate in harsh environments
Can withstand 250 degrees and an end load (1kN). - Various functions are provided
Free-range power supply (20 to 250VAC/DC), fail-safe function, and CE marking. - Easy to handle
No need for sensitivity adjustments and maintenance.
Line-up
Model name | SHT-120-RD | SHT-130-RD |
---|---|---|
Type | Standard type that withstands 250 degrees | Extension probe type that withstands 250 degrees |
Features | High sensitivity and solid design, the best standard model in this series. |
Dimensions can be adjusted to match the specific conditions |
Major applications | Various powders, pellets, and chips, incinerator ash, resins, clinkers (raw material for cement), resins, etc |
Incinerator ash, resins, clinker (raw material for cement) Mainly used for angled and vertical installations in upper positions |
Photograph |
Usages, use examples
Detects various powders, pellets, and chips, incinerator ash, resins, clinkers (raw material for cement), resins, etc.
Standard specifications
Model name | SHT-120-RD | SHT-130-RD | |
---|---|---|---|
Amplifier | Maximum detection sensitivity (Nominal specific gravity of material to be measured) |
0.02 | |
Input power source | 22 to 250 VAC/DC | ||
Configuration of output contact points | 2c (DPDT) | ||
Setting the output capacity | AC1250VA DC80W | ||
Maximum open/close voltage | 250V AC | ||
Maximum open/close current | 5A | ||
Power consumption | 3VA | ||
Allowable amplifier temperature | -20 to +70 degrees | ||
Case | Protection class | IP67 | |
Materials | Die-cast aluminum | ||
Wiring hole | M20×1.5 (2 pieces) | ||
Detection probe |
Connection | R1 1/2 (Many optional flanges are available *1) |
R1 1/2 (Many optional flanges are available) |
Materials | SUS304 | ||
Allowable temperature | -20 to +250 degrees | ||
Allowable pressure *2 | 1.0MPa | ||
Allowable load | 1KN (offset load) | - |