Strong electric conductive level switch
YCL type
- Ideal for a highly conductive substances liquid and powder
Also match to many adherent of material to be measured -
It measure the change of resistance between the detecting electrode and ground electrode. Ideal for a strong adhesion and conductivity at the material to be measured (miso or shampoo etc.).
In high durability without flexible retion to the sensor, has excellent cleaning.
Features, keys |Usage, use examples |Standard specifications
Features, keys
- Ideal for a conductive material to be measured
Ideal for strong conductive at the material to be measured, miso, shampoo, such as carbon. It also ideal for the adhesion of strong conductive material.
- Provides stable detection even in harsh environments
Can be used in harsh conditions such as high and low temperatures and high pressures, vacuum, vibration, and static electricity. - High durability and cleanability
In high durability without flexible retion to the sensor, has excellent cleaning. - lower power consumption eco-design
The power needed to drive the sensor has been decreased and it contributes to decreased costs and an improved ecology. This ecology design reduces costs 50% when compared with conventional models. - Various functions and free-range power supply are provided
Equipped with various functions including free-range power supply (20 to 250VAC/DC), a delay function, and a fail-safe function.
Usages, use examples
- Detects the conductive materials. (material, food, pharmaceuticals, cosmetics, and toiletries etc.
) - Detects the liquid interface of strong conductive liquid and non-conductive liquid.
- Decide the strong conductive liquid or non-conductive liquid in the CIP process of food processing.
- The material to be measured with a strong adherent conductive in each process.
Standard specifications
Amplifier
Input power source | 20 to 250 V AC/DC |
---|---|
Protection level | IP68 |
Allowable amplifier temperature | -10 to +60 degrees |
Contact point output | Relay contact point: 250V AC, 30V DC, 3A |
Sensor
Connection | R3/4 and various flanges (can be altered on request) |
---|---|
Material of the grounding and detecting electrodes | SCS13 |
Material of the insulating parts | Polyacetal, PTFE |
Allowable detector temperature | -10 to 80 degrees (*There is a high temperature type ) |
Allowable detector pressure | 2.0MPa |