HOME > Other sensing equipment > Substance change monitor meter CPS-24 series

Meters for supervising changes in substance characteristics

CPS-24 series
CPS-24 series
Sensors that detect leaks on floors, walls and distilled water pools. Oil leak detection is also possible.

Detects liquid leaking from tanks, piping, etc. A dedicated mounting stand for wall surfaces or gauge tubes is also available. This model is approved as an Intrinsically safe explosion-proof device (TIIS, ATEX).


*Liquid leakage detection / oil leakage detection
*Non-contact liquid detection in gauge tube.
*Liquid detection in gaps between double-walled tanks.

  • For liquid

In combination with a barrier, it also supports intrinsically safe explosion-proof (TIIS, ATEX), so it can be used as an oil spill detection.

 

Features, keys

  1. Leakage detection / Oil leak detection

  2. Detects leaks on floors and walls, distilled water reservoirs.
  3. Liquid detection inside the gauge tube.

  4. Can be detected from the outside of the gauge tube (glass tube) in a non-contact manner.
  5. Liquid detection in gaps between double-walled tanks.

  6. To be suspended the sensor to detected liquid in gaps between the double-walled tanks.
  7. Intrinsically safe explosion-proof

  8. Corresponds to intrinsically safe explosion-proof (TIIS, ATEX) in combination with a barrier.
 

Usages, use examples

  • Liquid leak detection / oil leak detection
  • Liquid detection in gauge tube.
  • Liquid detection in gaps between double-walled tanks.
 

Applications

Monitor material changes by measuring the capacitance values ??of liquids with different "dielectric constants". Ideal for material monitoring of various processes.

 

Standard specifications

Switch

Model neme CPS-24N
(non-explosion proof)
CPS-24Xi (explosion proof)
Power supply 7 to 36 DC 8 to 9 DC (Max.12V DC)
Current power supply 2mA (when OFF)
9mA (when ON)
1mA or less (when OFF)
2.2mA or more (when ON)
Contact (NPN / PNP) 200mA -
Sensitivity (detection distance) 0 to 5 mm (depending on the object to be measured and mounting method)
Operating ambient temperature -20 to +70 drgree
Connection M24 nut mounting
Material Case section: SUS304
Detection section: PTFE
Protection class IP67
Cable 5m, 10m
(0.5mm2 PVC 3-core cable)
5m, 10m
(0.75mm2 PVC 2-core cable)
Explosion-proof standard - TIIS: Exia‡UCT6Ga
ATEX: Exia‡U1GExiaCT6Ga


Relay barrier

Model name NDSU-822-230V NDSU-822-24V
Number of connected sensors 2
Power supply 30 to 230V AC, DC 10 to 30V AC, 10 to 40V DC
Power consumption 4VA 4W
Operating ambient temperature -20 to +60 degree
Explosion-proof standard TIIS: [ExiaGa]‡UC, [ExiaDa]‡VC,[ExiaMa]‡T
ATEX: Ex‡U(1)G[ExiaGa]‡UC, Ex‡U(1)D[ExiaDa]‡VC,
Ex‡T(M1)[ExiaMa]‡T

* For special specifications other than the above, please contact us.

  Please feel free to inquire us

  • Inquiries