Meters for supervising changes in substance characteristics
CPS-24 series
- Sensors that detect leaks on floors, walls and distilled water pools. Oil leak detection is also possible.
-
Detects liquid leaking from tanks, piping, etc. A dedicated mounting stand for wall surfaces or gauge tubes is also available. This model is approved as an Intrinsically safe explosion-proof device (TIIS, ATEX).
*Liquid leakage detection / oil leakage detection *Non-contact liquid detection in gauge tube. *Liquid detection in gaps between double-walled tanks.
In combination with a barrier, it also supports intrinsically safe explosion-proof (TIIS, ATEX), so it can be used as an oil spill detection.
Features, keys |Usage, use examples |Applications |Standard specifications
Features, keys
- Leakage detection / Oil leak detection Detects leaks on floors and walls, distilled water reservoirs.
- Liquid detection inside the gauge tube. Can be detected from the outside of the gauge tube (glass tube) in a non-contact manner.
- Liquid detection in gaps between double-walled tanks. To be suspended the sensor to detected liquid in gaps between the double-walled tanks.
- Intrinsically safe explosion-proof Corresponds to intrinsically safe explosion-proof (TIIS, ATEX) in combination with a barrier.
Usages, use examples
- Liquid leak detection / oil leak detection
- Liquid detection in gauge tube.
- Liquid detection in gaps between double-walled tanks.
Applications
Monitor material changes by measuring the capacitance values ??of liquids with different "dielectric constants". Ideal for material monitoring of various processes.
Standard specifications
Switch
Model neme | CPS-24N(non-explosion proof) | CPS-24Xi (explosion proof) |
---|---|---|
Power supply | 7 to 36 DC | 8 to 9 DC (Max.12V DC) |
Current power supply | 2mA (when OFF)9mA (when ON) | 1mA or less (when OFF)2.2mA or more (when ON) |
Contact (NPN / PNP) | 200mA | - |
Sensitivity (detection distance) | 0 to 5 mm (depending on the object to be measured and mounting method) | |
Operating ambient temperature | -20 to +70 drgree | |
Connection | M24 nut mounting | |
Material | Case section: SUS304 Detection section: PTFE | |
Protection class | IP67 | |
Cable | 5m, 10m(0.5mm2 PVC 3-core cable) | 5m, 10m(0.75mm2 PVC 2-core cable) |
Explosion-proof standard | - | TIIS: Exia‡UCT6Ga ATEX: Exia‡U1GExiaCT6Ga |
Relay barrier
Model name | NDSU-822-230V | NDSU-822-24V |
---|---|---|
Number of connected sensors | 2 | |
Power supply | 30 to 230V AC, DC | 10 to 30V AC, 10 to 40V DC |
Power consumption | 4VA | 4W |
Operating ambient temperature | -20 to +60 degree | |
Explosion-proof standard | TIIS: [ExiaGa]‡UC, [ExiaDa]‡VC,[ExiaMa]‡T ATEX: Ex‡U(1)G[ExiaGa]‡UC, Ex‡U(1)D[ExiaDa]‡VC,Ex‡T(M1)[ExiaMa]‡T |