HOME > Other sensing equipment > Substance change monitor meter MDL series

Meters for supervising changes in substance characteristics

MDL series
MDL series
In-line measurement and monitoring of substance changes is possible. Ideal for determining the mixture of multiple liquids and determining the type of liquid.

A high-precision capacitive amplifier enables various sensing. Can measure the mixing ratio and degree of mixing of two liquids, and to determine the type of liquid in the pipe. The sensor part has no moving parts and has a long life. Customization is also possible.


*The measured and set values are displayed on the OLED display.
*Freely changeable output of 4 contacts (alarm).

  • For liquid
  • For powder

By measuring the capacitance values ??of multiple substances with different "dielectric constants", quality control and analysis of the state of substances and contamination of foreign substances can be performed online.

 

Features, keys

  1. Using an OLED display that makes it easy to see changes in physical properties.

  2. High visibility is achieved and can be checked from various directions. "Measured value (%)", "capacitance value", etc. are displayed clearly and vividly.

  3. Can be set with 4 push buttons

  4. Initial adjustment can be easily set with push buttons while looking at the screen. Various settings and 4 contact points can be set and changed.

  5. 4 contact positions can be freely set and changed

  6. Any point in the measured value and operating direction (rising ON, descending ON, etc.) can be freely set and changed. It can also be used for alarms such as upper and lower limits. It is also displayed on and off the panel LED.
  7. Can measure changes in the physical properties of conductive substances from insulating substances.

  8. Various measurements of liquids with different dielectric constants, measurement of foreign substances mixed inside the liquid, etc. are possible. Powder can also be measured depending on the conditions.
  9. The shape and structure of the sensor can be designed according to the substance to be measured.

  10. The sensor part has no moving parts and has a long life, and the electrodes can be customized according to the customer's specifications.
 

Usages, use examples

  • Measurement of mixing ratio of liquids with different permittivity
  • Liquid discrimination in piping
  • Two-layer interface detection
 

Applications

Monitor material changes by measuring the capacitance values ??of liquids with different "dielectric constants". Ideal for material monitoring of various processes.

 

Standard specifications

Amplifier

Power input 20 to 250V AC, DC
Output 4 to 20mA DC (load resistance: 500Ω or less)
Power consumption 2.0W (DC24V), 3.0A (AC100V), 4.0VA (AC250V)
Measurement range 20pF-1000pF (standard type)
* Special type is also available
Measurement accuracy +-1%
Response speed Approx. 0.05sec to 15sec (variable)
Operating temperature -10 to +60 degree (no condensation)


Sensor

Material SUS304 (can be altered on request)
Connection Flange (pileline type)
Allowable temperature -10 to +80 degree (without condensation)
Allowable detector pressuree 2MPa (seal part) (connection part depends on each standard)

* For special specifications other than the above, please contact us.

  Please feel free to inquire us

  • Inquiries
Page Top