Optimum for detecting various substances and for controlling quality.

Determine if two types of liquid (liquid A or liquid B) are flowing in the pipe. Can be detected when nothing is flowing or when the liquid is interrupted.

  • For liquid

By measuring the difference in the "dielectric constant" of the liquid, it is possible to discriminate the flowing liquid and detect the empty state in-line. Also can be used as an interface level switch.

 

Features, keys

  1. Canceling the adhesion of liquid
    Even if the flowing liquid adheres to the sensor part, the adhered part is canceled and false detection does not occur.
  2. Supports harsh conditions such as high temperature and high pressure
    Supports difficult usage environments such as high temperature, high pressure, low temperature and vacuum.
  3. Free-range power supply and can be able to sequencer output
    Wide range of AC / DC 20-250V free power supply is adopted. Not only contact output but also various non-contact outputs are supported.
  4. Supports delay function and fail-safe in case of failure
    A delay function is also installed, and a fail-safe function is also installed as standard in case of failure.
  5. Intrinsically safe explosion-proof
    Intrinsically safe explosion-proof products (ExiaUBT5Ga conforming to international standards) are also available.


 

Usages, use examples

  • Oil / water discrimination switch (detects when water is mixed or interrupted)
  • Can also be used as an oil leak detection sensor for oil barriers, etc.@
  • In addition, discrimination of liquids with different dielectric constants (cleaning liquid and water, etc.)
 

Standard specifications

Amplifier

Input power source 20 to 250 V AC/DC
Power consumption 1.5VA or less
Protection level IP68
Allowable amplifier temperature -10 to +60 degrees
Contact output Relay contact point: 250V AC, 30V DC, 3A

Sensor

Connection R3/4 and various flanges (can be altered on request)
Material of the grounding and detecting electrodes SUS304 (can be altered on request)
Material of the insulating parts Polyacetal
Allowable detector temperature -10 to +80 degrees (180 degrees *)F
Allowable detector pressuree 2.0 MPa

* A high temperature type is also available on request.