HOME > Technical information > Free-range power supply

Free-range power supply

The electric powers supplied vary from one factory or plant to another.
Our sensors that are equipped with a free-range power supply can be used with various power voltages. Therefore, they can be used in any countries and regions in the world. The free-range power supply makes it possible to attain stable measurements under unstable power supply conditions. This page describes our free-range power supply and the power supply conditions in each country.

 

Free-range power supply

Ordinary sensor equipment operates according to fixed power voltages (100VAC or 200VAC in Japan). Many countries use different power voltages.Some devices on machines use DC power, such as 24VDC.If a different power is supplied, equipment that only accepts a fixed power voltage needs to have a power converter or it must be modified.

Need for free-range power supply

Some people believe that a free-range power supply is not needed inside Japan. However, even though users are in Japan, they may decide to export their machines and equipment outside Japan. These machines and equipment may be used in unstable power supply conditions. Therefore, a free-range power supply is becoming one of necessary aspects of sensor equipment.

A free-range power supply that can use a wide range of AC/DC current

Our products (capacitance level switch YAL and vibration level switch CV) have free-wide-range power supplies that work with 20 to 250 volts AC/DC. Because this power supply can be used across a wide range, these level switches can be used in almost all countries and regions in the world. This function can be used with almost all power outlets in the world, including countries in Europe.

Page Top
 

Electric power supply conditions in each country around the world

This page shows the power and voltage used in major countries around the world.
* Use the following data as general references only, because the actual power delivered may be different in certain areas and locations (such as in some cities).

District Country name For home use (V) For factory use (V) Frequency (Hz)
Asia Japan Single phase 100/200 Three phase 200 50/60
Korea Single phase 110/220 Three phase 200/220/380 60
China Single phase 220 Three phase 220/380 50
Taiwan Single phase 220 Three phase 220/380 60
India Single phase 230 Three phase 230/400 50
Oceania Australia Single phase 240 Three phase 240/415 50
New Zealand Single phase 230 Three phase 230/400 50
North America, South America Unites States of America Single phase 120/240 Three phase 120/208/240/265/277/460/480 60
Canada Single phase 120/240 Three phase 120/208/240 60
Brazil Single phase 127 Three phase 127/220 60
Argentina Single phase 220 Three phase 220/380 50
Europe U.K. Single phase 230 Three phase 230/400 50
Italy Single phase 220 Three phase 220/380
Germany Single phase 230 Three phase 230/400 50
France Single phase 230 Three phase 230/400 50
Russia Single phase 127/220 Three phase 220/380 50
Middle East Saudi Arabia Single phase 127/220 Three phase 220/380 60
Iran Single phase 230 Three phase 230/400 50
Africa Egypt Single phase 220 Three phase 220/380 50

  Please feel free to inquire us

  • Inquiries
Page Top